| Summing Up
We cannot emphasise too much that you are working around 240 volts. Please observe the law for your own safety and have a licensed electrician check your finished installation even if you haven't connected into the motorhomes 240 volt supply. TBS will have isolated units out in 2003. (see foot notes)
Bob Eustace
Acknowledgments - Special thanks to Collyn Rivers - Geoff Adcock (CMCA) - Daniel Shoulton (TBS Holland) - Michael Rush (Selectronic) - Dave Lambert (Rainbow Power Company).
Safety Notes - It is important that you read this!
Whilst it is legally OK to instal an inverter with a 240 volt socket attached to the inverter case into the 12 volt supply, we cannot stress how important it is for fellow motorhomers not to attempt to instal an inverter into the fixed motorhome wiring. DO NOT buy an inverter that doesn't have a three pin socket built directly into the housing unless you are having it installed by a licensed electrician who is familiar with RVs. There is a very valid reason for this in that inverters in Australia (at present) do not need electricity authority approval unless they are hard wired into a 240 volt system. In our view, this is a really poor show on the part of the authorities, but it certainly explains the huge price differences between the el-cheapo high wattage units and top line products such as the Australian made Selectronic and SEA . When buying an inverter we strongly suggest you ask the supplier the following:
- Is the inverter double insulated (electrically isolated between the battery and secondary voltage)?
- Can the inverter DC and AC circuits be earthed?
- Will the inverter work properly with an RCD?
If the answer is NO to ANY question please don't buy! Being double insulated means that should a fault develop, there is just about zero chance of 240 volt feeding back into the 12 volt system. As things stand at present there are a lot of units out there which run the risk of failing in this quite catastrophic way. RVs with everything metal "live" at 240 volts aren't an attractive proposition at all and it can be lethal. Some very responsible retailers have withdrawn a few models with this problem in the past few months. We were first made aware of this problem when a fellow club member pointed out some anomalies when using some brand inverters with safety switches (failing to trip). It is amazing what one can discover when pointed in the right direction. In using our TBS unit we make sure that the case is above earth (not in contact with metal) and its supply battery and case is not connected to the motorhome frame as it is not isolated. Our next motorhome will probably have a small Selectronic LD350-12 or an SEA Tempo unit. This is a far more expensive option ($1200.00) but you can't put a price on safety. We will certainly consider TBS if their units are then isolated.
Using ELCBs with inverters
We received the following information from Michael Rush of Selectronic in Bayswater, Victoria. Safety is very important when dealing with 240 volt so it is a good idea to take onboard Michael's comments. You can contact him at mrush@selectronic.com.au.
Use of ELCB protection devices on Selectronic inverters in portable situations
Introduction
The purpose of this report is to consider the use of Earth Leakage Circuit breaker (ELCB) protection devices with an inverter when used in a portable situation. We will investigate the type of ELCB which may be used, their usefulness and limitations.
Background
A Selectronic inverter takes power from a DC source, normally a battery, and converts it to AC power (normally 240V) suitable for running standard mains operated appliances. The output is just as hazardous as mains power therefore the same precautions should be taken when operating appliances from an inverter as you would from a normal mains outlet.
It is important that you read and understand the user manual that came with the inverter and follow the safety recommendations when using the inverter. If you have any questions after reading the user manual, please contact Selectronic and we will always be happy to assist.
When using the inverter, never operate any faulty appliances, and if in doubt have the appliance checked by a qualified person. Also never operate any appliance in a hazardous situation and always follow the appliance manufacturer's recommendations when operating any appliance from an inverter.
Using ELCBs in a portable situation
A portable situation is defined as connecting the inverter to the battery supply and using the inverter via the front power point. In this situation it is assumed the inverter is not connected to an earth stake, and that the output has not been connected MEN (earth and neutral connected together). When used in this configuration, the output is 'floating' above earth and any ELCB connected between the inverter and the appliance will not trip in the event of a fault within the appliance. This is because there is no return path for the 'fault' current and therefore the ELCB does not detect any imbalance in the load current. Likewise if there are more than one faulty appliance connected to the inverter via an ELCB, then the ELCB would still not trip. This is because any fault currents would flow between the appliances via their earth connection after the ELCB. Therefore the ELCB would again see a balanced current as no fault current would bypass the ELCB.
In a portable situation, the ELCB would only trip in the event of a fault between the live terminals and case within the inverter together with a fault between the live terminals and case within the appliance (assuming the appliance is earthed and not double insulated). These faults would need to be such to cause sufficient fault current to flow though the earth connection between the inverter and the appliance before the ELCB would trip.
When an ELCB is required to be used with an inverter in a portable situation, only an external plugin type or external inline type should be connected to the inverter. Under no circumstances should the GPO (power point) on the front of the inverter be removed or replaced with an ELCB type GPO.
Conclusion
The use of an ELCB with an inverter in a portable situation does offer the user a greater level of protection than not using one, however it should be noted that the ELCB will normally not trip in the event of an appliance fault. It is therefore important to ensure the appliances and the inverter are regularly checked for safety. |